ID No : | 818 Edit | Title: | Investigation of Loop Heat Pipe Survival and Restart After Extreme Cold Environment Exposure |
Summary / Review : | "NASA plans human exploration near the South Pole of the Moon, and other locations where the environment is extremely cold. This paper reports on the heat transfer performance of a loop heat pipe (LHP) exposed to extreme cold under the simulated reduced gravitational environment of the Moon. A common method of spacecraft thermal control is to use a LHP with ammonia working fluid. Typically, a small amount of heat is provided either by electrical heaters or by environmental design, such that the LHP condenser temperature never drops below the freezing point of ammonia. The concern is that a liquid-filled, frozen condenser would not restart, or that a thawing condenser would damage the tubing due to the expansion of ammonia upon thawing. This paper reports the results of an experimental investigation of a novel approach to avoid these problems. The LHP compensation chamber (CC) is conditioned such that all the ammonia liquid is removed from the condenser and the LHP is nonoperating. The condenser temperature is then reduced to below that of the ammonia freezing point. The LHP is then successfully restarted." (Author's abstract) |
Author(s) : |
Golliher, Eric; Ku, Jentung; Licari, Anthony; Sanzi, James, [Glenn Research Center; Goddard Space Flight Center] |
Publication Date: | 2010 |
Category(s) : |
Bases, industry and manufacturing / Mining / Lunar / Volatiles |
Web URL : |
http://hdl.handle.net/2060/20100024327
If this link is broken, please Add Comment below. We try to keep author contact details, and a backup copy in our offline library. |
PERMANENT code(s) : | L,U |
(Explanation of the last 3 rows above) |
In the row above, there are up to 4 possibilities: U = URL you can click on to get a copy instantly from another source on the internet, or request it from that source D = Downloadable from PERMANENT (such as because no other URL known...) L = LAN copy, PERMANENT has a digital copy but not downloadable from our website P = Paper copy in the PERMANENT office Typically, only 0 to 3 methods are available. |
NTRS : | 20100024327 |
Other Ref # : | NASA/TM-2010-216068, HT2009-88509, E-17103 |
Submitted by : | MEP |
Comments: |
Please add your thoughtful Comments to this paper after reading it. All comments are reviewed and approved before being posted publicly below. If you wish to submit a private comment to the curator, instead of a public comment, just write "Private" at the start of your comment. Corrections and suggested additions to our records are appreciated. |